Microtek UPS-EB 1000VA Inverter Price starts at Rs. 4,400. The lowest price of Microtek UPS-EB 1000VA Inverter is at Amazon. Microtek UPS-EB 1000VA Inverter is not available in other online stores. Microtek UPS-EB 1000VA Inverter is available in White, Grey colours across various online stores in India.
Microtek UPS-EB 1000VA Inverter Specifications
Warranty Details
Duration
2 Years
Warranty Available
Manufacturer Warranty
Warranty Service Type
, ,
Key Feature
Brand
Microtek
Under Voltage & Under Voltage Restoration
Regulated UPS mode
180 +/- 5 V
Unregulated UPS mode
100 +/- 10 V & 115 +/- 10 V
General Details
Inverter Type
Modified Sine Wave Inverter
Volt Ampere Rating
Above 1000VA
Battery Type
12 V BATTERY
Frequency (Mains Mode)
Same as Input (45-55 Hz.)
Output Voltage (UPS Mode)
200V-230V 10%
Frequency (UPS Mode)
50 Hz 0.1 Hz
Protection
Battery Deep Discharge, Reverse Polarity, DC Overvoltage
Voltage (Mains Mode)
100V~300V (Wide input voltage range), 180V~260V (Normal input voltage range)
Other Features
Visual Indicators
Mains On, UPS On, Switch Status, Smart Charge, Overload/ Short Circuit Trip, Charger Fuse Blown, Battery Low Trip and No Load Shutdown
Technology
Micro Controller Based Design
Battery Charging
Battery charging commences even at as low as 120 Volt Mains voltage
Switching from Mains to UPS & from UPS to Mains
Automatic
Output Waveform on UPS Mode
TPZi Waveform (TRAPE ZOIDAL WAVEFORM)
Audio Alarms
Mains fail, Charger fuse blown, battery low and no load shutdown
Battery Charging Current
Constant Charging Approx 10% of The Rated Battery Current in AH
Charger
Power Factor Controlled Boost Technology
Led Display
Mains On
Red
Battery Charged
GREEN LED STUDY
Battery Low
Red
No Load Shut Down
Red
Low Battery (Pre Alarm)
UPS ON+LOW BATTERY LED BLINKS
Overload
Red
Short Circuit
OVERLOAD BLINKING
Smart Charge
Red (Along with Mains On LED
Switch ON
White
Alarms
Charging Fuse Blown
Beeps Continuously for 10 seconds
Low Battery Trip
Beeps Continuously for 10 seconds
Overload
Beeps Continuously for 10 seconds
Low Battery (Pre Alarm)
Beeps every 10 seconds
Mains to UPS
Beeps every 2 seconds for 5 times
No Load Shut Down
Beeps Continuously for 10 seconds
Short Circuit
Beeps Continuously for 10 seconds
Power & Operating Requirements
Humidity
0-95 % RH non -condensing
Operating Temperature
0-45 DegreeC (32-113 DegreeF)
Storage Temperature
0-45 DegreeC (32-113 DegreeF)
What is in the Box
Items in the Box
Warranty Card
Disclaimer: Specifications shown may be different from the actual product. We cannot guarantee that the information provided on this page is 100% correct. Please check with the retailer before purchasing.